Time: 2016-08-26 View: 2745A, the correct selection of installation position
According to the requirements of the relevant departments, bridal chamber into the door, the complete set of gas alarm is installed in the kitchen near the gas meter, many domestic specifications of combustible gas alarm installed in the place such as kitchen. But because of the gas lighter than air, after leak if not found in time, will be to the upstairs through vents, floor drain, etc, is likely to lead to poisoning upstairs residents. Appear on market the alarm composite aircraft, unit installed in the kitchen, a machine can be in the bedroom, there are also many people hang alarm, respectively, in the kitchen, bathroom and bedroom.
Quite a few people know the alarm technology, are installed at least two alarm at their homes. Kitchen gas alarm can detect their own forget close or indoor gas pipeline leakage; Outlet installed in toilet nearby alarm, can be found in time or down the drain downstairs and channeling up the gas; And in the alarm of the bedroom, can remind people in his sleep.
Second, self-inspection of coping alarm at least once a month
Normal manufacturer of gas alarm are marked on the instructions for use, some brands of household combustible gas alarm also specifically indicated in the specification, residents of alarm at least once a month the introspection and self-checking method are introduced.
Residents, however, quite a few installed alarm, never the alarm in the home inspection, but subjective think that as long as the alarm didn´t ring, indicator lights on its in normal working.
In the alarm manual with "self-checking guides"
Armoured WeiXin warned that sensors are sensitive device, the sensitivity is determined by the reliability of the alarm, when the sensor or overall arriving at specified time limit, the alarm will back to calibrate the alarm or replace the sensor. Self-check alarm prospectus attached guidelines, but also in the case, the power supply is connected with a lighter or alcohol cotton ball in the alarm test at the bottom of the hole to release a small amount of gas or swing several times. There are some manufacturers to upgrade alarm sensor, alarm self-checking need to release a small amount of hydrogen gas or gas containing hydrogen.
Third, alarm, should be promptly cut off the gas and ventilation
Armoured WeiXin gas alarm manufacturer to tell you that when the alarm, is not that people want to poisoning, but showed a suspicious gas leak. State of the gas alarm alarm set point range has strict rules, the amount of the set value is lower than may cause a harm to human body. That is to say, when the alarm, a normal person even stood beside the leakage point, just in time to cut off the gas, ventilation, won´t cause bad effects to the body.
Four, give alarm on thin silk stockings, can prevent cockroaches into causing false alarm
In addition, due to the low temperatures in the north, long live the heat generated by the alarm will attract mosquitoes, cockroaches, etc, causing false alarm. Armoured WeiXin manufacturer recommendations, to identify the cause of the similar alarm condition, when available will alarm set up thin silk stockings, socks dense network can effectively block the cockroach infestation alarm, and good air permeability and alarm for suspected the sensitive degree of the gas would not be affected.