News Industry News Details
Industry NewsThe new product launches JTY- gd-dg312 smoke detector for battery factory aging box
Time: 2018-08-06 View: 2466
The new professional jty-gd-dg312 smoke detector of battery factory is introduced by kaiweisin. It adopts the infrared photoelectric sensor of special structure design, the reliable MCU, and the SMT patch processing technology, which has the characteristics of high sensitivity, stable and reliable, small power consumption, beautiful and durable, and convenient to use.
This product is not suitable for use in the following environments:
An environment in which smoke is normally trapped. There are large dust, water mist, steam, oil fog pollution, corrosion gas environment. The relative humidity is greater than 97%. Environment with ventilation speed greater than 5m/ s.
How it works
The photoelectric sensor with special structure design combined with MCU with reliable performance can effectively detect the smoke generated after the initial stage of smoldering fire or the subsequent generation. When smoke into the detector, the scattering light source, light receiving element feel light intensity, the received light intensity has certain linear relationship, and smoke concentration detector parameters on site constantly gathering, analysis, and judgment, when confirm the intensity of light field data reaches the threshold, start relay output, when returned to normal in the environment of smoke detectors automatically return to normal working condition. Self-test: under normal circumstances, press the self-test button, the detector carries out its own internal function test, relay output.
This product is not suitable for use in the following environments:
An environment in which smoke is normally trapped. There are large dust, water mist, steam, oil fog pollution, corrosion gas environment. The relative humidity is greater than 97%. Environment with ventilation speed greater than 5m/ s.
How it works
The photoelectric sensor with special structure design combined with MCU with reliable performance can effectively detect the smoke generated after the initial stage of smoldering fire or the subsequent generation. When smoke into the detector, the scattering light source, light receiving element feel light intensity, the received light intensity has certain linear relationship, and smoke concentration detector parameters on site constantly gathering, analysis, and judgment, when confirm the intensity of light field data reaches the threshold, start relay output, when returned to normal in the environment of smoke detectors automatically return to normal working condition. Self-test: under normal circumstances, press the self-test button, the detector carries out its own internal function test, relay output.