Industry NewsIn family life, which is easy to cause gas leak explosion
Time: 2016-12-02 View: 2721First, the gas cooker ignition failure, lead to gas leakage, causing the gas explosion accidents.
Gas ignition failure reasons:
1, air door not good, cause the too big, the air inlet air too much increase the risk of explosion.
2, lighter contact form dirt or micro switch failure.
3, batteries.
4, the poor contact of circuit.
5, over voltage protection.
6, pipes get clogged.
7, inappropriate position of ignition needle.
The second, indoor gas pipeline damage, resulting in gas leakage and explosion accidents.
The main reason for the damage of indoor gas pipe are:
1, long-term contact with water or corrosive substances, cause the pipeline corrosion.
2, home decoration, wall hanging items such as external force, the pipeline interface is loose.
3, pipeline anticorrosion paint falls off (layer) did not make up brush, metal and long-term exposure to air, cause the pipeline corrosion.
Third, gas meter damage, resulting in gas leakage.
The main cause of gas meter leak:
1, extended use internals aging, resulting in gas leakage.
2, the external force to break in, cause the body or joint damage, gas table lead to leakage.
Fourth, gas hose burst, fall off, lead to gas leakage.
30% of the gas leak is due to ruptured hose, fall off, the cause of hose burst loss are:
1, on both ends of the hose clip or not clamp is loose.
2, hose are used, the aging crack.
3, the use of easy corrosion and aging of inferior hose.
4, failed to make hose bitten by mice bad, sharp objects scraped, etc.
Fifth, the pot liquid overflow, douse the burning flame, lead to gas leakage.
The cause of the pot liquid overflow are:
1, the fire cooking, boiling soup, processing is not timely.
2, forget the soup, cooking porridge, researchers for a long time to leave.
Sixth, forget to close the gas valve, lead to gas leakage.
Forget to close the gas valve of the reasons are:
1, lack of consciousness of valve.
2, emergency to go out or have an emergency event handling.
3, old person or child forget to close the valve.
4, short-term after stopping air supply.
Seventh, gas valve interface damage, leading to a gas leak.
The cause of damage of gas valves:
1, long-term switch valve, the valve is loose.
2, disrepair.
3, the valve is corrosion.
Eighth, gas stoves, damage, resulting in leakage explosion.
Gas stoves damaged reasons:
1, gas stove itself disrepair.
2, gas stove was found to be of poor quality.
3, human touch force and friction caused damage.
Ninth, SiGai gas pipeline, resulting in gas leakage.
The reason why SiGai pipeline:
1, beautiful for indoor, to transform gas pipeline.
2, to increase the fuel gas facilities, add tee to extend the line itself.
3, small covet interests for the gas meter measurement or less, not steal tube.
The tenth irregularities, gas company, lead to gas leakage.
The irregularities of gas company mainly include:
1, gas related units in the new operation of pipe network or network maintenance when replacement is not in place.
2, no completion inspection and acceptance, or stop using pipeline operation of blindly.
3, replacement or repair of equipment to conduct a comprehensive inspection for ventilation.
4, accidental leakage occurs not arrived in time, or for the appropriate disposal measures cause secondary leakage.
5, not according to stipulations on a regular basis door security check or security, propaganda is not in place.
For people´s life and property safety, it is recommended that the installation of gas alarm alarm device.